Variable or Fixed Volume Variable Volume
Volume Range Min (uL) 0.5
Volume Range Max (uL) 12.5
Accuracy (%/uL) 2.50/0.313
Repeatability/Precision (%/uL) 1.60/0.20
Autoclavable Yes
Volume Increment 0.01

Flawlessly measuring and transporting liquids depend on your electronic pipette in use. Finding the ideal unit to meet demands of your application can be a daunting task with many electronic pipettes accessible in the market. Do not stress yourself as Lab.Equipment is here to make things a lot easier for you! The Thermo Fisher 16-ch 0.5-12.5 µl maybe the perfect solution for refining your lab protocols and operations, if not, you can surely discover the right unit for your application requirements by going through our FAQ, review, and comparison of the 16-ch 0.5-12.5 µl with other pipettes so continue reading below.

Since Lab.Equipment offers 877 pipettes from all 16 pipette manufacturer such as Thermo Fisher, this is the only place you will find true product descriptions carefully drafted for you. Unlike any other distributor around, we would not push you a catalog filled with repeating buzzwords, jargons, and propriety terms a lot manufacturers give to confuse us persevering lab staffs. We can help you filter the unnecessary and save time as well as budget with real descriptions meticulously written to lead you in purchasing the right Pipette for your laboratory application, whether it is with this E1-ClipTip Electronic 16-ch 0.5-12.5 µl or not.

If you must carry out pipetting tasks that are time sensitive while ensuring accuracy or if you are working on 96-well or 384-well microplates for applications such as PCR, aliquoting, ELISA, enzyme activity and protein assays, electronic pipettes are best for you. These are recommended for workrooms with high pipetting demands like biochemistry, microbiology, and neuroscience labs to name a few. Compared to using manual pipettes, an electronic pipette like the Thermo Fisher E1-ClipTip Electronic 16-ch 0.5-12.5 µl is cost-effective, can increase lab productivity by lowering a lab associate’s workload, and can be an alternative to automated pipetting systems.


How much measured liquid solutions can you dispense and transfer with the electronic 16-ch 0.5-12.5 µl?

The electronic E1-ClipTip Electronic 16-ch 0.5-12.5 µl is built to particularly discharge liquid solutions between 0.5 - 12.5 uL volumes.


I carry out tasks with high pipetting demands, what type of electronic pipette should I invest on?

Precisely as well as immediately place 96-, 384-, or 1536-well plates for your enzyme assays or drug screenings with an electronic multi-channel pipette like the convenient and lightweight 16-ch 0.5-12.5 µl.


Is the Thermo Fisher 16-ch 0.5-12.5 µl a fixed or variable volume pipette?

The electronic, multichannel Thermo Fisher E1-ClipTip Electronic 16-ch 0.5-12.5 µl is adjustable and capable of offering variable volume based on the particular assay or application you are running. Change volumes accordingly in increments of 0.01.


Do you require a PDF quote for the Thermo Fisher 16-ch 0.5-12.5 µl Pipette?

We will not waste your time playing phone tag with a high pressure sales rep, easily use the Instant Quote tool above and you will get a quote for the Thermo Fisher 16-ch 0.5-12.5 µl delivered to your inbox within 30 seconds! No pesky sales reps calling on you we promise.


Compared to other electronic multichannel variable volume pipettes, how accurate is the 16-ch 0.5-12.5 µl?

The Thermo Fisher 16-ch 0.5-12.5 µl can reliably transfer and discharge liquid samples with its 2.5/0.313 accuracy.


Against other electronic multichannel variable volume pipettes, how precise is the Thermo Fisher 16-ch 0.5-12.5 µl?

Ensure reproducibility of your pipetting tasks through the Electronic Multichannel Variable Volume 16-ch 0.5-12.5 µl that offers 1.6/0.20 repeatability.


How simple is the 16-ch 0.5-12.5 µl to clean and maintain?

The Thermo Fisher 16-ch 0.5-12.5 µl is autoclavable, ensuring sterility, hygiene, and safety for use in your other laboratory applications.


Any questions on the Thermo Fisher 16-ch 0.5-12.5 µl Laboratory Pipette that we missed answering for you here?

Feel free to ask us through the live chat to the right, our Contact us page, or email us at [email protected] and we will get back to you asap with friendly response.




Product Size Each

Accuracy ±2.5 to 12.0%

Compatible Tips ClipTip 384 12.5

Color Code Pink

Description E1-ClipTip 16-channel

Number of Channels 16

Volume (Metric) Range 0.5 to 12.5µL

Model E1-ClipTip

Product Type ClipTip 384 and ClipTip 12.5 tips and compatible E1-ClipTip models do not have interlocking technology

Increments 0.01µL

Precision ≤1.6 to 12.0%


With enhanced versatility and customization, the Thermo Scientific™ E1-ClipTip™ Electronic Multichannel Pipette automates daily 96-and 384-well microplate pipetting tasks with the sealed in security of Thermo Scientific™ ClipTip™ technology. Enjoy pipetting again with optimum functionality for every application and user preference. Feel the difference.

Innovative ClipTip interlocking tip interface technology†

  • Tip is locked and sealed in place until ejected— no dropped tips that waste valuable samples

  • Complete seal to secure the sample volume in each tip for enhanced accuracy and precision

  • Tips are attached and ejected with a light touch— eliminates the frustration of banging tips on the pipette

Unified operation for multiple users and environments

  • Personalized user interface and password protection ensure consistent operation among multiple users.

  • Electronic operation to help you enjoy pipetting again

  • Designed for optimum comfort and ease of use, the electronic tip ejection and index finger pipetting action let your thumb relax during pipetting.


Two operating options ensure optimal function for every application

Choose a step based Matrix or Presets with settings for your most common applications

MyPipette™ - One click access for more efficient and unified pipetting

Customize your main menu view by organizing icons in your preferred order or creating shortcuts for your favorite programs and pipetting functions. You can also protect important settings from unintentional editing with a password.

Store up to 20 programs

Tired of continuous editing? The Programs function allows you to store 20 your most common Matrix or Presets protocols with a specific name.

A pipette for every application

Choose from single channels, 8-16 channel multichannels, or 6- 12-channel adjustable tip spacing Equalizer multichannel pipettes within the volume range of 0.5-1250µL

Track your pipette

Service and calibration trackers remind you when the pipette needs to be sent to serviced.

Liquid specific calibrations

Higher quality results with liquid specific calibrations.

Li-Ion battery

Long lasting performance and fast recharging.

Flexible re-charging

Use either charging stand or a plug, you decide.

2-year warranty

With convenient web registration.

Thermo Fisher Scientific is a global provider of lab instruments ranging from pipettes, centrifuges, to baths, ultra-low temperature freezers, and more — all ergonomically designed to achieve maximum performance for life sciences, industrial & applied science, and clinical & diagnostics applications. Created to deliver high-performing solutions to scientists faced with complex analytical demands, Thermo Fisher Scientific lab equipment and software are utilized in a diverse range of industries including: pharmaceutical, biotechnology, academic, government, environmental and industrial research, and clinical research. With approximately 65,000 employees stationed in different regions worldwide, Thermo Fisher Scientific addresses manufacturing and distribution requirements with ease.

Explore Thermo Fisher Scientific's robust product line featured on Lab.Equipment:

The product descriptions and attribute groupings and assignments on this page are protected by copyright all rights reserved. If copied you will be persecuted against to the full extent of the law including infringement charges up to $10,000 USD per page of content.

[Pipette] Accuracy (%/uL): 2.50/0.313
[Pipette] Autoclavable: Yes
[Pipette] Repeatability/Precision (%/uL): 1.60/0.20
[Pipette] Variable or Fixed Volume: Variable Volume
[Pipette] Volume Increment: 0.01
[Pipette] Volume Range Max (uL): 12.5
[Pipette] Volume Range Min (uL): 0.5