Eppendorf Reference 2 Single Channel Fixed 2.5mL Pipette from Eppendorf
Variable or Fixed Volume | Fixed Volume |
Volume Range Min (uL) | 2500 |
Volume Range Max (uL) | 2500 |
Accuracy (%/uL) | 0.6/15 |
Repeatability/Precision (%/uL) | 0.2/5 |
Autoclavable | Yes |
Finding the most suitable manual pipettor to measure and transport your fluid samples flawlessly can be a daunting task with plenty of choices visible in the market. Don’t worry as Lab.Equipment is here to cut the frills for you! Find out how the Eppendorf Single Channel Fixed 2.5mL suits your accuracy and precision needs. If it does not make your cut, read through our review, FAQ, and comparison of the Single Channel Fixed 2.5mL to other pipettes below to get the perfect unit for your protocols.
Get comprehensive lab pipette information carefully curated by Lab.Equipment. Carrying 877 pipettes from all 16 pipettor manufacturer including Eppendorf, this is the only place you will read real product descriptions carefully written for you. We would not push you a product catalog stuffed with the same buzzwords, jargons, and terms a lot manufacturers has "made up" to perplex us diligent lab staffs.
Dispensing and transporting liquid samples are basic tasks done in biochemistry, medical and scientific, chemistry, and molecular biology laboratories. If you need cutting-edge pipettors that can withstand daily laboratory use and are effortless to maintain, you can go for a manual pipette like the Eppendorf Eppendorf Reference 2 Single Channel Fixed 2.5mL. A manual pipette is more affordable compared to electronic units and is ideal for use in laboratory applications that do not really have high pipetting requirements.
How much measured liquid solutions can you transport and dispense with the manual Single Channel Fixed 2.5mL?
The manual Eppendorf Reference 2 Single Channel Fixed 2.5mL is engineered to particularly transfer liquid solutions up to 2,500uL volumes.
I perform all-around pipetting tasks dealing with low amounts of liquid samples, what type of manual pipette should I purchase?
You can enhance routine pipetting tasks for your biology, pharmaceutical, scientific, or chemical laboratories with a manual single-channel pipette like the convenient and lightweight Eppendorf Single Channel Fixed 2.5mL.
Is the Eppendorf Single Channel Fixed 2.5mL a fixed or variable volume pipette?
The fixed volume manual single channel Eppendorf Single Channel Fixed 2.5mL can help minimize risks of errors from dispensing unreliable volumes or cross-contamination. A fixed volume pipette such as the Single Channel Fixed 2.5mL can dispense the exact, fixed amount of dense or viscous liquid solutions, making way for a faster workflow without needing to change volumes on a regular basis.
Interested in requesting a PDF quote for the Eppendorf Single Channel Fixed 2.5mL Pipette?
Simply use the Instant Quote tool above and you will receive a quote for the Eppendorf Single Channel Fixed 2.5mL emailed to your inbox within 30 seconds! We promise no high pressure sales representatives calling you.
How accurate is the Eppendorf Single Channel Fixed 2.5mL against other manual single channel fixed volume pipettes?
Transfer and dispense liquid samples confidently with the Eppendorf Single Channel Fixed 2.5mL as it presents 0.6/15 accuracy.
In comparison with other manual single channel fixed volume pipettes, how precise is the Eppendorf Single Channel Fixed 2.5mL?
Acquire close values and guarantee reproducibility of your pipetting tasks through the Manual Single Channel Fixed Volume Single Channel Fixed 2.5mL that provides 0.2/5 repeatability.
How easy is the Single Channel Fixed 2.5mL to maintain and clean?
The Eppendorf Single Channel Fixed 2.5mL is autoclavable, ensuring safety, hygiene, as well as sterility for use in your other lab applications.
Any questions on the Eppendorf Single Channel Fixed 2.5mL Laboratory Pipette that we missed answering for you here?
Just ask via live chat to the right, our Contact Us page, or email [email protected] and we will get back to you with a prompt and friendly response.
The Eppendorf Reference 2 is our premium product. Besides improved of its ergonomics the focus design lay on providing the most accurate results possible, optimum user safety, reliability and robustness for a long service life. The innovative single button operation is not only fast and easy, but it also allows active aerosol reduction and thus protects the user, the sample and the pipette. The sturdy handle manufactured with stainless steel protects the pipette from impact and in combination with the spring loaded bumpers the Reference 2 is likely to stay within calibration even if it takes a fall. These high levels of security make the Reference 2 ideal for use with precious liquids, or in any application requiring extremely high levels of accuracy. When there can be no compromise on quality and reproducibility, Eppendorf’s Reference 2 is an ideal instrument for these Liquid Handling applications.
Single-Button Operation
Lower Operating forces for aspiration/dispensing/tip ejection limit strain on the user.
Allows users to move more quickly through their pipetting tasks by not having to move the thumb from side to side to eject tips.
With the ability to eject a tip immediately following dispensing, aerosol contamination of your pipette is considerably reduced.
User-Friendly Secondary Adjustment
For liquids other than aqueous solutions pipettes have to be adjusted. The Reference 2 provides easy possibility to do so, leaving the factory settings untouched. Suggestions for settings ar provided. Reset back to manufacturer setting just as quick and easy.
The unique one-button operation offers a fast and ergonomic handling with reduced operating effort and active aerosol reduction. To avoid an accidental tip ejection a clear haptic feedback is provided
The spring loaded tip cone improves user to user reproducibility and improved ergonomics by lowering tip attachment force
The Reference 2 multi-channel offers a high flexibility incl a spring-loaded tip cone which can be switched on/off optionally
The secondary adjustment supports the easy adjustment of your Reference 2 for the most accurate pipetting of different liquids or other external conditions without the need for a full calibration
The quick lock enables an easy cleaning and maintenance of your pipette
The outstanding precision and accuracy of Reference 2 provides reliable results
4 digit volume display with magnifying window to allow for easier volume identification
External edges made from stainless steel equip the pipette with outstanding robustness
An embedded RFID chip contains all relevant data regarding the pipette and offers with Eppendorf TrackIT a simple identification and documentation
For more than 70 years, Eppendorf has been innovating and providing premium lab instruments and consumables for various facilities working on liquid handling, sample preparation, and cell handling applications. Offering an extensive range of versatile lab equipment including lab pipettes, automated pipetting systems, spectrometers, ultra-temperature freezers plus robust lab supplies such as pipette tubes, sample tubes, and microtiter plates, Eppendorf makes way for unparallaled lab efficiency and improved workflows. With products engineered to meet the highest standards, Eppendorf guarantees the best quality products possible — ideal not just for academic and commercial research, pharmaceutical, clinical, and biotechnological laboratories, but also for industries including the food, forensics, and chemical sectors.
Explore Eppendorf's innovative product line available on Lab.Equipment including:
The product descriptions and attribute groupings and assignments on this page are protected by copyright all rights reserved. If copied you will be persecuted against to the full extent of the law including infringement charges up to $10,000 USD per page of content.