Eppendorf Reference 2 Single Channel Fixed 2mL Pipette from Eppendorf

Variable or Fixed Volume Fixed Volume
Volume Range Min (uL) 2000
Volume Range Max (uL) 2000
Accuracy (%/uL) 0.6/12
Repeatability/Precision (%/uL) 0.2/4
Autoclavable Yes

Correctly measuring and transferring liquid samples depend on your manual pipette in use. Looking for the perfect one to meet requirements of your specific application can be an overwhelming task with a plethora of manual pipettes available in the market. Do not fret as Lab.Equipment is here to simplify your unit selection process! Learn how the Eppendorf Single Channel Fixed 2mL suits your accuracy and precision needs. If it does not make your cut, read about our review, FAQ, and comparison of the Single Channel Fixed 2mL to other pipettes below to find the right unit for your application requirements.

Since Lab.Equipment showcases 877 pipettes from all 16 pipettor manufacturer such as Eppendorf, this is the only site you will find true product descriptions meticulously written for you. Unlike any other single distributor around, we would not shove you a product portfolio stuffed with repeating buzzwords, jargons, and propriety terms many manufacturers give to puzzle us hard-working lab staffs. We can help you filter the unnecessary and not waste time as well as budget with real descriptions carefully written to lead you in finding the perfect Pipette for your lab application, whether it is with this Eppendorf Reference 2 Single Channel Fixed 2mL or not.

Transporting and dispensing liquid samples are basic tasks done in biochemistry, medical and scientific, chemistry, and molecular biology labs. Need durable pipettes that can withstand daily lab use and are simple to maintain? You can opt for a manual pipette like the Eppendorf Eppendorf Reference 2 Single Channel Fixed 2mL. Compared to electronic ones, a manual pipette is more economical and is recommended for use in specific lab applications that do not really have high pipetting requirements.


How much measured liquids can you transfer and discharge with the manual Single Channel Fixed 2mL?

The manual Eppendorf Reference 2 Single Channel Fixed 2mL is set-up to completely dispense liquid solutions up to 2000uL.


I execute routinary pipetting tasks dealing with little amounts of liquids, what type of manual pipette should I shop?

A manual single-channel pipette like the convenient and lightweight Eppendorf Single Channel Fixed 2mL can help improve regular pipetting tasks for your pharmaceutical, scientific, chemical, or biological labs.


Is the Eppendorf Single Channel Fixed 2mL a fixed or variable volume pipette?

The fixed volume manual single channel Eppendorf Single Channel Fixed 2mL can help minimize risks of errors caused by dispensing improper volumes or cross-contamination.. A fixed volume pipette like the Single Channel Fixed 2mL can dispense the same, fixed amount of dense or viscous liquid solutions, giving way to a quicker work process without the need to change volumes often.


Want to request a PDF quote for the Eppendorf Single Channel Fixed 2mL Pipette?

We will not waste your time playing phone tag with a high pressure sales rep, simply use the Instant Quote tool above and you will get a quote for the Eppendorf Single Channel Fixed 2mL delivered to your inbox within 30 seconds! No pesky sales reps calling on you we promise.


How accurate is the Eppendorf Single Channel Fixed 2mL compared to other manual single channel fixed volume pipettes?

Dispense and transfer liquid samples confidently with the Eppendorf Single Channel Fixed 2mL as it provides 0.6/12 accuracy.


In comparison with other manual single channel fixed volume pipettes, how precise is the Eppendorf Single Channel Fixed 2mL?

Ensure reproducibility of your pipetting applications with the Manual Single Channel Fixed Volume Single Channel Fixed 2mL that presents 0.2/4 repeatability.


How effortless is the Single Channel Fixed 2mL to maintain and clean?

The Eppendorf Single Channel Fixed 2mL is autoclavable, ensuring sterility, hygiene, as well as safety for use in your other lab applications.


Do you have any questions about the Eppendorf Single Channel Fixed 2mL Laboratory Pipette that we missed answering for you here?


Feel free to ask us through the live chat to the right, our Contact us page, or email us at [email protected] and we will get back to you asap with friendly response.




The Eppendorf Reference 2 is our premium product. Besides improved of its ergonomics the focus design lay on providing the most accurate results possible, optimum user safety, reliability and robustness for a long service life. The innovative single button operation is not only fast and easy, but it also allows active aerosol reduction and thus protects the user, the sample and the pipette. The sturdy handle manufactured with stainless steel protects the pipette from impact and in combination with the spring loaded bumpers the Reference 2 is likely to stay within calibration even if it takes a fall. These high levels of security make the Reference 2 ideal for use with precious liquids, or in any application requiring extremely high levels of accuracy. When there can be no compromise on quality and reproducibility, Eppendorf’s Reference 2 is an ideal instrument for these Liquid Handling applications.

Single-Button Operation

  • Lower Operating forces for aspiration/dispensing/tip ejection limit strain on the user.

  • Allows users to move more quickly through their pipetting tasks by not having to move the thumb from side to side to eject tips.

  • With the ability to eject a tip immediately following dispensing, aerosol contamination of your pipette is considerably reduced.

User-Friendly Secondary Adjustment

For liquids other than aqueous solutions pipettes have to be adjusted. The Reference 2 provides easy possibility to do so, leaving the factory settings untouched. Suggestions for settings ar provided. Reset back to manufacturer setting just as quick and easy.

  • The unique one-button operation offers a fast and ergonomic handling with reduced operating effort and active aerosol reduction. To avoid an accidential tip ejection a clear haptic feedback is provided

  • The spring loaded tip cone improves user to user reproducibility and improved ergonomics by lowering tip attachment force

  • The Reference 2 multi channel offers a high flexibility incl a spring-loaded tip cone which can be switched on/off optionally

  • The secondary adjustment supports the easy adjustment of your Reference 2 for the most accurate pipetting of different liquids or other external conditions without the need for a full calibration

  • The quick lock enables an easy cleaning and maintenance of your pipette

  • The oustanding precision and accuracy of Reference 2 provides reliable results

  • 4 digit volume display with magnifying window to allow for easier volume identification

  • External edges made from stainless steel equip the pipette with outstanding robustness

  • An embedded RFID chip contains all relevant data regarding the pipette and offers with Eppendorf TrackIT a simple identification and documentation

For more than 70 years, Eppendorf has been innovating and providing premium lab instruments and consumables for various facilities working on liquid handling, sample preparation, and cell handling applications. Offering an extensive range of versatile lab equipment including lab pipettes, automated pipetting systems, spectrometers, ultra-temperature freezers plus robust lab supplies such as pipette tubes, sample tubes, and microtiter plates, Eppendorf makes way for unparallaled lab efficiency and improved workflows. With products engineered to meet the highest standards, Eppendorf guarantees the best quality products possible — ideal not just for academic and commercial research, pharmaceutical, clinical, and biotechnological laboratories, but also for industries including the food, forensics, and chemical sectors.

Explore Eppendorf's innovative product line available on Lab.Equipment including: 

The product descriptions and attribute groupings and assignments on this page are protected by copyright all rights reserved. If copied you will be persecuted against to the full extent of the law including infringement charges up to $10,000 USD per page of content.

[Pipette] Accuracy (%/uL): 0.6/12
[Pipette] Autoclavable: Yes
[Pipette] Repeatability/Precision (%/uL): 0.2/4
[Pipette] Variable or Fixed Volume: Fixed Volume
[Pipette] Volume Range Max (uL): 2000
[Pipette] Volume Range Min (uL): 2000

Back To Top
We are fully compliant with the GDPR laws. We promise to safeguard your data and protect your privacy rights.