Finnpipette F2 Single Channel F2 Variable 5-50 ul Pipette from Thermo Fisher

Variable or Fixed Volume Variable Volume
Volume Range Min (uL) 5
Volume Range Max (uL) 50
Accuracy (%/uL) 10/0.50
Repeatability/Precision (%/uL) 8.0/0.080
Autoclavable Yes

With hundreds of manual pipette choices purchasable in the market, finding the ideal one to measure and dispense your liquid samples correctly can be a challenging task. Don’t fret as Lab.Equipment is here to help you find the ideal unit for your application! Find out how the Thermo Fisher F2 Variable 5 µL conform to your precision and accuracy needs. If it does not make your cut, read through our review, FAQ, and comparison of the F2 Variable 5 µL to other pipettes below to discover the best unit for your protocols.

Since Lab.Equipment carries 877 pipettes from all 16 pipette manufacturer including Thermo Fisher, this is the only site you will see real product descriptions thoroughly drafted for you. Unlike any other single distributor around, we would not give you a catalog filled with repeating buzzwords, jargons, and propriety terms most manufacturers present to perplex us hard-working lab staffs. We can help you cut through the noise and not waste time as well as budget with real descriptions meticulously written to lead you in getting the ideal Pipette for your specific lab application, whether it is with this Finnpipette F2 Single Channel F2 Variable 5 µL or not.

Measuring and dispensing liquids are basic tasks done in molecular biology, biochemistry, medical and scientific, and chemistry labs. If you require cutting-edge pipettors that can withstand daily laboratory use and are hassle-free to maintain, you can purchase a manual pipette like the Thermo Fisher Finnpipette F2 Single Channel F2 Variable 5 µL. A manual pipette is more economical compared to electronic units and is recommended for use in specific lab applications that do not really have high pipetting needs.


How much measured liquid solutions can you transport and dispense with the manual F2 Variable 5 µL?

Rely on the manual Finnpipette F2 Single Channel F2 Variable 5 µL to precisely discharge liquids between 5 - 50 uL volumes.


What manual pipette should I buy if I perform miscellaneous pipetting tasks dealing with small amounts of liquid samples?

A manual single-channel pipette like the lightweight and ergonomic Thermo Fisher F2 Variable 5 µL can help optimize regular pipetting tasks for your biology, pharmaceutical, scientific, or chemical labs.


Is the Thermo Fisher F2 Variable 5 µL a fixed or variable volume pipette?

The manual, single channel Thermo Fisher Finnpipette F2 Single Channel F2 Variable 5 µL is adjustable and capable of offering variable volume depending on the particular application or assay you are working on.


Interested in requesting a PDF quote for the Thermo Fisher F2 Variable 5 µL Pipette?

Just fill out the Instant Quote tool above and get a quote for the Thermo Fisher F2 Variable 5 µL delivered to your inbox within 30 seconds. No phone tag with high pressure and pesky sales representatives, we promise!


In comparison with other manual single channel variable volume pipettes, how accurate is the F2 Variable 5 µL?

Dispense and transfer fluid samples confidently with the Thermo Fisher F2 Variable 5 µL as it comes with 10/0.5 accuracy.


In comparison with other manual single channel variable volume pipettes, how precise is the Thermo Fisher F2 Variable 5 µL?

Ensure reproducibility of your pipetting applications through the Manual Single Channel Variable Volume F2 Variable 5 µL that comes with 8/0.08 repeatability.


How effortless is the F2 Variable 5 µL to clean and maintain?

The Thermo Fisher F2 Variable 5 µL is autoclavable, ensuring safety, hygiene, as well as sterility for use in your other laboratory applications.


Any questions on the Thermo Fisher F2 Variable 5 µL Lab Pipette that we missed answering for you here?

Feel free to ask us through the live chat to the right, our Contact us page, or email us at [email protected] and we will get back to you asap with friendly response.




Product Size Each

Accuracy +/-3.00 to 0.60%

Compatible Tips Finntip Flex 200, Finntip Flex 300, Finntip 250 universal, Finntip 200 Extended

Color Code Yellow

Volume (Metric) Range 5 to 50μL

Model Finnpipette™ F2

Increments 0.1µL

Precision 2.5 to 0.3%

Eliminate the possible effects of hand warmth on the accuracy of measurements with Thermo Scientific™ Finnpipette™ F2 Adjustable-Volume Pipettes, which feature Advanced Volume Gearing (AVG)—a thermally-isolated self-supporting modular volume adjustment mechanism that enhances pipetting performance. Because the AVG mechanism is separated from the pipette body, its accuracy and precision are significantly improved.

  • Large Ergovisio display with white numbers on black background for increased visibility

  • Double-action pipetting button; rotating upper part prevents accidental volume alteration

  • Light, smooth pipetting action enables better results over longer periods

  • Fully autoclavable

Thermo Fisher Scientific is a global provider of lab instruments ranging from pipettes, centrifuges, to baths, ultra-low temperature freezers, and more — all ergonomically designed to achieve maximum performance for life sciences, industrial & applied science, and clinical & diagnostics applications. Created to deliver high-performing solutions to scientists faced with complex analytical demands, Thermo Fisher Scientific lab equipment and software are utilized in a diverse range of industries including: pharmaceutical, biotechnology, academic, government, environmental and industrial research, and clinical research. With approximately 65,000 employees stationed in different regions worldwide, Thermo Fisher Scientific addresses manufacturing and distribution requirements with ease.

Explore Thermo Fisher Scientific's robust product line featured on Lab.Equipment:

The product descriptions and attribute groupings and assignments on this page are protected by copyright all rights reserved. If copied you will be persecuted against to the full extent of the law including infringement charges up to $10,000 USD per page of content.

[Pipette] Accuracy (%/uL): 10/0.50
[Pipette] Autoclavable: Yes
[Pipette] Repeatability/Precision (%/uL): 8.0/0.080
[Pipette] Variable or Fixed Volume: Variable Volume
[Pipette] Volume Range Max (uL): 50
[Pipette] Volume Range Min (uL): 5