Voyager II 8-Channel 5-125 Pipette from Integra

Volume Range Min (uL) 5
Volume Range Max (uL) 125
Accuracy (%/uL) 1.60
Repeatability/Precision (%/uL) 0.35
Autoclavable No
Volume Increment 0.1

With multiple electronic pipette units on hand in the market, looking for the best unit to measure and transfer your fluid samples flawlessly can be an overwhelming task. Don’t stress yourself out as Lab.Equipment is here to simplify things for you! The Integra Voyager II 4722 may give the accuracy and precision your particular application demands but if not, you will certainly decide on the ideal pipettor to meet your requirements based on our review, FAQ, and comparison of the 4722 with other pipettes purchasable so proceed on scrolling down.

Since Lab.Equipment carries 877 pipettors from all 16 pipette manufacturer like Integra, this is the only place you will see true product descriptions thoroughly drafted for you. Unlike any other single distributor around, we would not provide you a portfolio showing repeating buzzwords, jargons, and propriety terms a lot manufacturers present to baffle us diligent lab staffs. We can help you cut through all the noise and save time as well as budget with true descriptions meticulously written to lead you in finding the most fit Pipette for your lab application, whether it is with this Voyager II 4722 or not.

If you must perform pipetting tasks that are time sensitive while ensuring accuracy or if you are working on 96-well or 384-well microplates for applications such as PCR, aliquoting, ELISA, enzyme activity and protein assays, electronic pipettes can do the work for you. These are ideal for workrooms with high pipetting demands like biochemistry, neuroscience, and microbiology laboratories to name a few. As an alternative to automated pipetting systems, an electronic pipette like the Integra Voyager II 4722 is cost-efficient, increasing laboratory productivity by reducing a lab associate’s workload compared to using manual pipettes.


How much measured liquids can you dispense and transfer with the electronic 4722?

The electronic Voyager II 4722 is built to specifically transfer liquid samples between 5 - 125 uL volumes.


I complete tasks with high pipetting requirements, what type of electronic pipette should I go for?

An electronic multi-channel pipette like the lightweight and ergonomic 4722 can quickly as well as precisely place 96-, 384-, or 1536-well plates for your enzyme assays or drug screenings


Interested in requesting a PDF quote for the Integra 4722 Pipette?

Simply use the Instant Quote tool above and you will receive a quote for the Integra 4722 delivered to your inbox within 30 seconds! We promise no high pressure sales representatives calling you.


How accurate is the Integra 4722 compared to other electronic multichannel pipettes?

Dispense and transfer liquid samples with confidence using the Integra 4722 as it presents 1.6 accuracy.


In comparison with other electronic multichannel pipettes, how precise is the Integra 4722?

Achieve close values and guarantee reproducibility of your pipetting tasks with the Electronic Multichannel 4722 that presents 0.35 repeatability.


Any questions on the Integra 4722 Lab Pipette that we missed answering for you here?

Feel free to ask us through the live chat to the right, our Contact us page, or email us at [email protected] and we will get back to you asap with friendly response.




Moving multiple samples from one labware to another as individual transfers is both a tedious and an error prone task.

VOYAGER II pipettes feature motorized tip spacing, enabling parallel transfer of multiple samples between labware of different sizes and formats. The tip spacing can be changed by the simple push of a button, no manual adjustments or two handed operations are needed. This not only boosts your pipetting productivity but also reduces the risk of developing repetitive strain injuries (RSI).

The VOYAGER II adjustable tip spacing pipettes are available in 4, 6, 8 and 12 channel versions and expand anywhere from 4.5 mm to 33 mm. This provides access toa wide range of labware formats such as microplates, tube racks or gel chambers. The VOYAGER II pipette is the ideal companion for a wide variety of Genomic, Proteomic and Cell Culture applications!

Save hours of pipetting

Instead of going back and forth with a single channel pipette between different labware, the VOYAGER II allows you to transfer multiple samples at once. This increases pipetting productivity significantly, while also reducing pipetting errors, as the number of transfers is minimized.

Transferring samples from 1.5 ml microcentrifuge tubes to a 96 well plate using a VOYAGER II multichannel pipette is 8 times faster compared to a single channel pipette.

GripTips snap on

Do your pipette tips ever loosen, leak or fall off? This is a common issue in laboratories, caused by the use of universal pipette tips. Such tips require “hammering on” which stretches the shape of the pipette tip. The tip will start moving back to its original shape and away from the tip cone. This can cause leaking, misaligned tips and even pipette tips that completely fall off the pipette!

This will never happen with any VOYAGER II electronic pipette / GripTip combination. Featuring a low attachment and ejection forces, GripTips effortlessly snap onto the tip fittings. This means GripTips are always firmly attached and perfectly aligned, regardless of how many side well touch offs are performed. You no longer have to hammer your pipette tips on or worry about pipette tips falling off!

Intuitive user interface

Same as all INTEGRA electronic pipettes, VOYAGER II pipettes feature a color screen and proven touch wheel user interface for quick and comprehensive menu navigation. Simply by moving a finger over the touch wheel, menus and settings can be accessed.

A choice of ten predefined pipetting modes provides users with convenient solutions for the most common liquid handling tasks. Standard pipetting routines, such as repeat dispensing, can be executed with minimal setup time. For more elaborate pipetting routines, up to 40 personalized custom programs can be created and saved.

VOYAGER II pipettes allow the tip spacing to expand anywhere between 4.5 mm and 33 mm at the push of a button. The motorized tip spacing offers many advantages over manual tip spacing adjustments:

  • Single handed operation leaves the other hand free to handle labware.

  • On the fly access to up to 3 user-defined tip spacings.

  • These user defined tip spacings are saved. No need to memorize spacings of different labware formats.

Since 1965, Integra has been committed to addressing the pipetting and media preparation requirements of various organizations in research, medical, and quality control industries. Integra delivers high-precision, accurate and reproducible results with product offerings including manual and electronic pipettes, pipetting accessories, aspiration systems, peristaltic pumps, media preparation supplies, and microplate dispensers. Complete with sales channels in the USA, Canada, China, UK, France, Germany, Austria and Switzerland plus more than 100 distribution partners worldwide, Integra is capable of developing and distributing exceptional quality, ergonomic instruments to any part of the globe.

Integra's high-functioning products available on Lab.Equipment are listed below:

The product descriptions and attribute groupings and assignments on this page are protected by copyright all rights reserved. If copied you will be persecuted against to the full extent of the law including infringement charges up to $10,000 USD per page of content.

[Pipette] Accuracy (%/uL): 1.60
[Pipette] Autoclavable: No
[Pipette] Repeatability/Precision (%/uL): 0.35
[Pipette] Volume Increment: 0.1
[Pipette] Volume Range Max (uL): 125
[Pipette] Volume Range Min (uL): 5

Back To Top