Viaflo II 4626 Pipette from Integra

Volume Range Min (uL) 2
Volume Range Max (uL) 50
Accuracy (%/uL) 1.50
Repeatability/Precision (%/uL) 0.40
Autoclavable No
Volume Increment 0.05

Given plenty of electronic pipette choices available in the market, looking for the most suitable unit to measure and dispense your liquid samples flawlessly can be a daunting task. Don’t stress yourself out as Lab.Equipment can make things a lot easier for you! The Integra Viaflo II 4626 may give the accuracy and precision your laboratory application demands but if not, you will certainly decide on the perfect pipettor to meet your protocols from our review, FAQ, and comparison of the 4626 to other pipettors on hand so go on reading.

Get complete lab pipette information carefully curated by Lab.Equipment. Carrying 877 pipettes from all 16 pipette manufacturer such as Integra, this is the only place you will see true product descriptions meticulously written for you. We would not provide you a catalog displaying exactly the same buzzwords, jargons, and terms many manufacturers present to confuse us committed lab staffs.

Whether you are working on 96-well or 384-well microplates for applications such as enzyme activity and protein assays, ELISA, aliquoting, PCR, and more or if you have to perform pipetting tasks that are time sensitive while ensuring accuracy, electronic pipettes can do the work for you. These are recommended for workrooms with high pipetting demands like biochemistry, microbiology, and neuroscience laboratories to name a few. Compared to using manual pipettes, an electronic pipette like the Integra Viaflo II 4626 is cost-effective, can increase laboratory productivity by minimizing a lab associate’s workload, and can be an alternative to automated pipetting systems.


How much measured liquid solutions can you transfer and discharge with the electronic 4626?

The electronic Viaflo II 4626 is built to exactly hand over liquid solutions from 2 - 50 uL volumes.


What type of electronic pipette should I get if I perform tasks with high pipetting demands?

An electronic multi-channel pipette like the lightweight and convenient 4626 can accurately as well as precisely place 96-, 384-, or 1536-well plates for your drug screenings or enzyme assays


Looking for a PDF quote for the Integra 4626 Pipette?

We will not waste your time playing phone tag with a high pressure sales rep, simply use the Instant Quote tool above and you will get a quote for the Integra 4626 delivered to your inbox within 30 seconds! No pesky sales reps calling on you we promise.


How accurate is the Integra 4626 in comparison with other electronic multichannel pipettes?

Dispense and transfer fluid samples with confidence with the Integra 4626 as it presents 1.5 accuracy.


Compared to other electronic multichannel pipettes, how precise is the Integra 4626?

Obtain close values and secure reproducibility of your pipetting applications with the Electronic Multichannel 4626 that comes with 0.4 repeatability.


Any questions on the Integra 4626 Lab Pipette that we missed answering for you here?

Don't hesitate to ask us via live chat to the right, our Contact Us page, or email [email protected] and we will get back to you as soon as we can with a friendly response.




VIAFLO II electronic pipettes together with INTEGRA’s wide range of GripTips form a perfect pipetting system. GripTips snap into place with minimal tip loading effort, providing a secure connection. GripTips never fall off and are always perfectly aligned, resulting in superior accuracy and precision results.

The ultra lightweight, well balanced design of the VIAFLO II pipettes feature unsurpassed multichannel pipetting ergonomics, even during prolonged pipetting sessions.

The color screen together with the easy to navigate touch wheel user interface promote ease of set up and operation. All VIAFLO II pipettes offer a choice of predefined pipetting modes covering typical applications as well as custom multi-step programs for specific tasks.

GripTips snap on

Do your pipette tips ever loosen, leak or fall off? This is a common issue in laboratories, caused by the use of universal pipette tips. Such tips require “hammering on” which stretches the shape of the pipette tip rim. The stretched pipette tip rim immediately starts moving back to its original shape, away from the tip cone. This can cause leaking, misaligned tips and even pipette tips that completely fall off the pipette!

This will never happen with any VIAFLO II electronic pipette / GripTip combination. Featuring a low attachment force and a low ejection force, GripTips effortlessly snap onto the tip fittings and are easily ejected. Also, GripTips feature a high lateral resistance once attached to the VIAFLO IIpipettes. This means GripTips are always firmly attached and perfectly aligned, regardless of how many side well touch offs are performed. You no longer have to hammer your pipette tips on or worry about pipette tips falling off!

Versatile user interface

A color screen and proven touch wheel interface offer quick and comprehensive menu navigation. Simply by moving a finger over the touch wheel, menus and settings can be accessed. All menus are spelled out on the clear to read screen making memorizing abbreviations unnecessary

A choice of ten predefined pipetting model provides users with convenient solutions for the most common liquid handling tasks. Standard pipetting routines, such as repeat dispensing or serial dilutions can be executed with minimal setup time.

For more elaborate pipetting routines, up to 40 personalized custom programs can be created and saved. Custom programs can contain up to 98 individual steps based upon the following basic operations: Aspirate, Dispense, Mix, Purge and Prompt

Ergonomic design

The new VIAFLO II pipette offers perfect balance, an ultra lightweight design, unsurpassed operational comfort and is ideal for both left and right handed users. The effortless tip attachment and ejection forces add to the ergonomic benefits that accompany the use of VIAFLO II electronic pipettes.

Since 1965, Integra has been committed to addressing the pipetting and media preparation requirements of various organizations in research, medical, and quality control industries. Integra delivers high-precision, accurate and reproducible results with product offerings including manual and electronic pipettes, pipetting accessories, aspiration systems, peristaltic pumps, media preparation supplies, and microplate dispensers. Complete with sales channels in the USA, Canada, China, UK, France, Germany, Austria and Switzerland plus more than 100 distribution partners worldwide, Integra is capable of developing and distributing exceptional quality, ergonomic instruments to any part of the globe.

Integra's high-functioning products available on Lab.Equipment are listed below:

The product descriptions and attribute groupings and assignments on this page are protected by copyright all rights reserved. If copied you will be persecuted against to the full extent of the law including infringement charges up to $10,000 USD per page of content.

[Pipette] Accuracy (%/uL): 1.50
[Pipette] Autoclavable: No
[Pipette] Repeatability/Precision (%/uL): 0.40
[Pipette] Volume Increment: 0.05
[Pipette] Volume Range Max (uL): 50
[Pipette] Volume Range Min (uL): 2

Back To Top
We are fully compliant with the GDPR laws. We promise to safeguard your data and protect your privacy rights.