Viaflo II 4641 Pipette from Integra

Volume Range Min (uL) 0.5
Volume Range Max (uL) 12.5
Accuracy (%/uL) 2.00
Repeatability/Precision (%/uL) 0.80
Autoclavable No
Volume Increment 0.01

Flawlessly measuring and transferring fluid samples highly depend on your electronic pipette in use. Looking for the most suitable one to meet demands of your application can be an overwhelming task with many electronic pipettes purchasable in the market. Don’t stress yourself out as Lab.Equipment is going to make things a lot easier for you! The Integra 4641 might be the ideal solution for refining your laboratory process and operations, but if not, you can surely discover the best unit for your protocols based off our FAQ, review, and comparison of the 4641 with other pipettes so keep on scrolling below.

Since Lab.Equipment showcases 877 pipettes from all 16 pipettor manufacturer including Integra, this is the only site you will find real product descriptions thoroughly drafted for you. Unlike any other single distributor around, we would not give you a product portfolio filled with the exact same buzzwords, jargons, and propriety terms a lot manufacturers offer to puzzle us diligent lab staffs. We can help you cut through all the noise and not waste time as well as budget with real descriptions meticulously written to lead you in finding the most fit Pipette for your specific application, whether it is with this Viaflo II 4641 or not.

Whether you are working on 96-well or 384-well microplates for applications such as PCR, aliquoting, ELISA, enzyme activity and protein assays, and more or if you need to do pipetting tasks that are time sensitive while ensuring accuracy, electronic pipettes are ideal for you. These are best for workrooms with high pipetting demands like biochemistry, microbiology, and neuroscience labs to name a few. As an alternative to automated pipetting systems, an electronic pipette like the Integra Viaflo II 4641 is cost-efficient, increasing lab productivity by lowering a lab associate’s workload compared to using manual pipettes.


How much measured liquids can you dispense and transfer with the electronic 4641?

The electronic Viaflo II 4641 is configured to correctly pass on liquids between 0.5 - 12.5 uL volumes.


What type of electronic pipette should I purchase if I do tasks with high pipetting requirements?

Accurately as well as precisely place 96-, 384-, or 1536-well plates for your enzyme assays or drug screenings with an electronic multi-channel pipette like the convenient and lightweight 4641.


Looking for a PDF quote for the Integra 4641 Pipette?

Just fill out the Instant Quote tool above and receive a quote for the Integra 4641 emailed to your inbox within 30 seconds. No phone tag with high pressure and pesky sales representatives, we promise!


How accurate is the Integra 4641 compared to other electronic multichannel pipettes?

Discharge and transfer liquids confidently using the Integra 4641 as it comes with 2 accuracy.


Against other electronic multichannel pipettes, how precise is the Integra 4641?

Secure reproducibility of your pipetting applications through the Electronic Multichannel 4641 that provides 0.8 repeatability.


Any questions on the Integra 4641 Lab Pipette that we missed answering for you here?

Don't hesitate to inquire via live chat to the right, our Contact Us page, or email [email protected] and we will get back to you as soon as we can with a friendly response.




VIAFLO II electronic pipettes together with INTEGRA’s wide range of GripTips form a perfect pipetting system. GripTips snap into place with minimal tip loading effort, providing a secure connection. GripTips never fall off and are always perfectly aligned, resulting in superior accuracy and precision results.

The ultra lightweight, well-balanced design of the VIAFLO II pipettes feature unsurpassed multichannel pipetting ergonomics, even during prolonged pipetting sessions.

The color screen together with the easy to navigate touch wheel user interface promote ease of set up and operation. All VIAFLO II pipettes offer a choice of predefined pipetting modes covering typical applications as well as custom multi-step programs for specific tasks.

GripTips snap on

Do your pipette tips ever loosen, leak or fall off? This is a common issue in laboratories, caused by the use of universal pipette tips. Such tips require “hammering on” which stretches the shape of the pipette tip rim. The stretched pipette tip rim immediately starts moving back to its original shape, away from the tip cone. This can cause leaking, misaligned tips and even pipette tips that completely fall off the pipette!

This will never happen with any VIAFLO II electronic pipette / GripTip combination. Featuring a low attachment force and a low ejection force, GripTips effortlessly snap onto the tip fittings and are easily ejected. Also, GripTips feature a high lateral resistance once attached to the VIAFLO IIpipettes. This means GripTips are always firmly attached and perfectly aligned, regardless of how many side well touch offs are performed. You no longer have to hammer your pipette tips on or worry about pipette tips falling off!

Versatile user interface

A color screen and proven touch wheel interface offer quick and comprehensive menu navigation. Simply by moving a finger over the touch wheel, menus and settings can be accessed. All menus are spelled out on the clear to read screen making memorizing abbreviations unnecessary.

A choice of ten predefined pipetting model provides users with convenient solutions for the most common liquid handling tasks. Standard pipetting routines, such as repeat dispensing or serial dilutions can be executed with minimal setup time.

For more elaborate pipetting routines, up to 40 personalized custom programs can be created and saved. Custom programs can contain up to 98 individual steps based upon the following basic operations: Aspirate, Dispense, Mix, Purge and Prompt.

Ergonomic design

The new VIAFLO II pipette offers perfect balance, an ultra lightweight design, unsurpassed operational comfort and is ideal for both left and right handed users. The effortless tip attachment and ejection forces add to the ergonomic benefits that accompany the use of VIAFLO II electronic pipettes.

Since 1965, Integra has been committed to addressing the pipetting and media preparation requirements of various organizations in research, medical, and quality control industries. Integra delivers high-precision, accurate and reproducible results with product offerings including manual and electronic pipettes, pipetting accessories, aspiration systems, peristaltic pumps, media preparation supplies, and microplate dispensers. Complete with sales channels in the USA, Canada, China, UK, France, Germany, Austria and Switzerland plus more than 100 distribution partners worldwide, Integra is capable of developing and distributing exceptional quality, ergonomic instruments to any part of the globe.

Integra's high-functioning products available on Lab.Equipment are listed below:

The product descriptions and attribute groupings and assignments on this page are protected by copyright all rights reserved. If copied you will be persecuted against to the full extent of the law including infringement charges up to $10,000 USD per page of content.

[Pipette] Accuracy (%/uL): 2.00
[Pipette] Autoclavable: No
[Pipette] Repeatability/Precision (%/uL): 0.80
[Pipette] Volume Increment: 0.01
[Pipette] Volume Range Max (uL): 12.5
[Pipette] Volume Range Min (uL): 0.5

Back To Top
We are fully compliant with the GDPR laws. We promise to safeguard your data and protect your privacy rights.