Voyager II 8-Channel 50-1250 Pipette from Integra

Volume Range Min (uL) 50
Volume Range Max (uL) 1250
Repeatability/Precision (%/uL) 0.30
Autoclavable No
Volume Increment 1

Accurately measuring and transferring liquids depend on your electronic pipette in use. Looking for the best one to meet requirements of your particular lab application can be an intimidating task with various electronic pipettes purchasable in the market. Don’t worry as Lab.Equipment can cut the frills for you! The Integra 4724 might be the best solution for refining your lab operations and process, if not, you can surely find the best unit for your requirements by reading our FAQ, review, and comparison of the 4724 with other pipettes so keep scrolling down.

Since Lab.Equipment carries 877 pipettes from all 16 pipette manufacturer like Integra, this is the only website you will read real product descriptions carefully drafted for you. Unlike any other single distributor around, we would not push you a product catalog showing exactly the same buzzwords, jargons, and propriety terms most manufacturers has "made up" to confuse us hard-working lab staffs. We can help you cut through all the noise and save time as well as budget with true descriptions meticulously written to lead you in finding the most fit Pipette for your specific application, whether it is with this Voyager II 4724 or not.

Whether you are working on 96-well or 384-well microplates for applications such as enzyme activity and protein assays, ELISA, aliquoting, PCR, and more or if you must carry out pipetting tasks that are time sensitive while ensuring accuracy, electronic pipettes are recommended for you. These are best for workrooms with high pipetting demands like neuroscience, biochemistry, and microbiology laboratories to name a few. As an alternative to automated pipetting systems, an electronic pipette like the Integra Voyager II 4724 is cost-efficient, improving lab productivity by lowering a lab staff's workload compared to using manual pipettes.


How much measured liquid solutions can you transfer and dispense with the electronic 4724?

The electronic Voyager II 4724 is designed to completely dispense liquids between 50 - 1,250 uL volumes.


What type of electronic pipette should I go for if I carry out tasks with high pipetting demands?

Precisely and quickly place 96-, 384-, or 1536-well plates for your enzyme assays or drug screenings with an electronic multi-channel pipette like the ergonomic and lightweight 4724.


Want to request a PDF quote for the Integra 4724 Pipette?

We guarantee not to waste your time with pesky and high pressure sales representatives calling you. Easily use the Instant Quote tool above and receive the quote for Integra 4724 within 30 seconds!


In comparison with other electronic multichannel pipettes, how accurate is the 4724?

The Integra 4724 can reliably dispense and transport liquid samples with its 1.2 accuracy.


Compared to other electronic multichannel pipettes, how precise is the Integra 4724?

Get close values and ensure reproducibility of your pipetting tasks through the Electronic Multichannel 4724 that offers 0.3 repeatability.


Do you have any questions about the Integra 4724 Laboratory Pipette that we missed answering for you here?

Don't hesitate to inquire via live chat to the right, our Contact Us page, or email [email protected] and we will get back to you as soon as we can with a friendly response.




Moving multiple samples from one labware to another as individual transfers is both a tedious and an error prone task.

VOYAGER II pipettes feature motorized tip spacing, enabling parallel transfer of multiple samples between labware of different sizes and formats. The tip spacing can be changed by the simple push of a button, no manual adjustments or two handed operations are needed. This not only boosts your pipetting productivity but also reduces the risk of developing repetitive strain injuries (RSI).

The VOYAGER II adjustable tip spacing pipettes are available in 4, 6, 8 and 12 channel versions and expand anywhere from 4.5 mm to 33 mm. This provides access toa wide range of labware formats such as microplates, tube racks or gel chambers. The VOYAGER II pipette is the ideal companion for a wide variety of Genomic, Proteomic and Cell Culture applications!

Save hours of pipetting

Instead of going back and forth with a single channel pipette between different labware, the VOYAGER II allows you to transfer multiple samples at once. Thisincreases pipetting productivity significantly, while also reducing pipetting errors, as the number of transfers is minimized.

Transferring samples from 1.5 ml microcentrifuge tubes to a 96 well plate using a VOYAGER II multichannel pipette is 8 times faster compared to a single channel pipette.

GripTips snap on

Do your pipette tips ever loosen, leak or fall off? This is a common issue in laboratories, caused by the use of universal pipette tips. Such tips require “hammering on” which stretches the shape of the pipette tip. The tip will start moving back to its original shape and away from the tip cone. This can cause leaking, misaligned tips and even pipette tips that completely fall off the pipette!

This will never happen with any VOYAGER IIelectronic pipette / GripTip combination. Featuring a low attachment and ejection forces, GripTips effortlessly snap onto the tip fittings. This means GripTips are always firmly attached and perfectly aligned, regardless of how many side well touch offs are performed. You no longer have to hammer your pipette tips on or worry about pipette tips falling off!

Intuitive user interface

Same as all INTEGRA electronic pipettes, VOYAGER II pipettes feature a color screen and proven touch wheel user interface for quick and comprehensive menu navigation. Simply by moving a finger over the touch wheel, menus and settings can be accessed.

A choice of ten predefined pipetting modes provides users with convenient solutions for the most common liquid handling tasks. Standard pipetting routines, such as repeat dispensing, can be executed with minimal setup time. For more elaborate pipetting routines, up to 40 personalized custom programs can be created and saved.

VOYAGER II pipettes allow the tip spacing to expand anywhere between 4.5 mm and 33 mm at the push of a button. The motorized tip spacing offers many advantages over manual tip spacing adjustments:

  • Single handed operation leaves the other hand free to handle labware.

  • On the fly access to up to 3 user-defined tip spacings.

  • These user defined tip spacings are saved. No need to memorize spacings of different labware formats.

Since 1965, Integra has been committed to addressing the pipetting and media preparation requirements of various organizations in research, medical, and quality control industries. Integra delivers high-precision, accurate and reproducible results with product offerings including manual and electronic pipettes, pipetting accessories, aspiration systems, peristaltic pumps, media preparation supplies, and microplate dispensers. Complete with sales channels in the USA, Canada, China, UK, France, Germany, Austria and Switzerland plus more than 100 distribution partners worldwide, Integra is capable of developing and distributing exceptional quality, ergonomic instruments to any part of the globe.

Integra's high-functioning products available on Lab.Equipment are listed below:

The product descriptions and attribute groupings and assignments on this page are protected by copyright all rights reserved. If copied you will be persecuted against to the full extent of the law including infringement charges up to $10,000 USD per page of content.

[Pipette] Autoclavable: No
[Pipette] Repeatability/Precision (%/uL): 0.30
[Pipette] Volume Increment: 1
[Pipette] Volume Range Max (uL): 1250
[Pipette] Volume Range Min (uL): 50

Back To Top
We are fully compliant with the GDPR laws. We promise to safeguard your data and protect your privacy rights.